<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"><channel><title>Baoshengda FSR Engineering Articles</title><link>https://bsdfsr.com/en/articles/</link><description>Flexible pressure sensor selection, applications and customization</description><language>en</language><item><title>FSR loading and unloading curves: separate hysteresis from drift in a sample review</title><link>https://bsdfsr.com/en/articles/fsr-loading-unloading-hysteresis-review/</link><guid isPermaLink="true">https://bsdfsr.com/en/articles/fsr-loading-unloading-hysteresis-review/</guid><description>Compare raw FSR outputs at matched reference loads in both directions, then check timing and assembly conditions. Keep curve-fitting and independent verification data separate and define the metric and review scope.</description></item><item><title>Does high unloaded FSR resistance mean a broken circuit? Review incoming-test conditions</title><link>https://bsdfsr.com/en/articles/fsr-unloaded-resistance-incoming-review/</link><guid isPermaLink="true">https://bsdfsr.com/en/articles/fsr-unloaded-resistance-incoming-review/</guid><description>Check model-specific criteria, meter mode, range, contact and assembly conditions before judging high unloaded FSR resistance. Record controlled loading response and distinguish pending confirmation from failure against an agreed criterion.</description></item><item><title>FSR readings hitting a limit: check display, ADC and analog front end separately</title><link>https://bsdfsr.com/en/articles/fsr-clipped-readings-signal-chain-review/</link><guid isPermaLink="true">https://bsdfsr.com/en/articles/fsr-clipped-readings-signal-chain-review/</guid><description>Distinguish a display ceiling from raw ADC codes, input voltage and analog front-end range. Keep synchronized records and configurations before treating a flat curve as a sensor force limit, consistency result or usable calibration data.</description></item><item><title>Can an FSR calibration transfer to a revised seat design? Review changes and comparisons</title><link>https://bsdfsr.com/en/articles/fsr-seat-design-change-calibration-review/</link><guid isPermaLink="true">https://bsdfsr.com/en/articles/fsr-seat-design-change-calibration-review/</guid><description>Retain the earlier baseline when seat foam, surface layers or supports change. Separate structure, sensor replacement and software adjustment, then identify which assembly and test conditions support retaining or replacing a calibration.</description></item><item><title>FSR temperature checks: in-temperature readings, recovery and compensation</title><link>https://bsdfsr.com/en/articles/fsr-temperature-readings-recovery-compensation/</link><guid isPermaLink="true">https://bsdfsr.com/en/articles/fsr-temperature-readings-recovery-compensation/</guid><description>Review FSR readings at the test temperature separately from recovery measurements. Keep raw, recalibrated and compensated results distinct, with specimen, assembly, loading, temperature location and processing versions recorded.</description></item><item><title>Reviewing multipoint FSR acquisition: positions, channels and adjacent responses</title><link>https://bsdfsr.com/en/articles/fsr-multipoint-channel-position-review/</link><guid isPermaLink="true">https://bsdfsr.com/en/articles/fsr-multipoint-channel-position-review/</guid><description>Map sensing positions, wiring, acquisition channels and display locations before testing adjacent responses. Separate shared force paths from acquisition effects and identify scan timing and display-processing limits.</description></item><item><title>Reviewing FSR state thresholds: align actions, signals and decisions in time</title><link>https://bsdfsr.com/en/articles/fsr-state-threshold-time-record-review/</link><guid isPermaLink="true">https://bsdfsr.com/en/articles/fsr-state-threshold-time-record-review/</guid><description>Separate sensor hysteresis from decision-rule hysteresis. Align actions, raw and processed signals, and states before comparing threshold settings, with clear limits for replay and assembly retesting.</description></item><item><title>Before adding an FSR protective layer: liquid paths, venting and force transfer</title><link>https://bsdfsr.com/en/articles/fsr-protective-layer-liquid-vent-review/</link><guid isPermaLink="true">https://bsdfsr.com/en/articles/fsr-protective-layer-liquid-vent-review/</guid><description>Review liquid exposure, construction-specific venting and force transfer before protecting an FSR. Keep manufacturer-specific sealing advice and complete-assembly validation distinct.</description></item><item><title>FSR part-to-part variation and repeatability: what should a sample review compare?</title><link>https://bsdfsr.com/en/articles/fsr-repeatability-part-to-part-comparison/</link><guid isPermaLink="true">https://bsdfsr.com/en/articles/fsr-repeatability-part-to-part-comparison/</guid><description>Separate same-sensor repetitions, different-sensor comparisons and remounting. Keep raw and calibrated results distinct and agree how sample consistency supports a purchasing decision.</description></item><item><title>FSR signal problems after assembly: connection or force transfer?</title><link>https://bsdfsr.com/en/articles/fsr-assembly-signal-troubleshooting/</link><guid isPermaLink="true">https://bsdfsr.com/en/articles/fsr-assembly-signal-troubleshooting/</guid><description>Compare pre- and post-assembly FSR signals, separate termination and tail checks from force-transfer checks, and record changes for the teams responsible.</description></item><item><title>Testing FSR samples for seats and mattresses: occupancy or force measurement?</title><link>https://bsdfsr.com/en/articles/fsr-seat-mattress-sample-validation/</link><guid isPermaLink="true">https://bsdfsr.com/en/articles/fsr-seat-mattress-sample-validation/</guid><description>Define whether a seat or mattress project needs occupancy detection, relative loading changes or numerical force measurement. Use task and process records to agree on assembly, loading and unloading tests. Acceptance criteria and supply scope require project review.</description></item><item><title>Custom FSR Sensors: What to Prepare Before an Inquiry | Baoshengda</title><link>https://bsdfsr.com/en/articles/fsr-custom-project-requirements/</link><guid isPermaLink="true">https://bsdfsr.com/en/articles/fsr-custom-project-requirements/</guid><description>Before a custom FSR inquiry, describe the application, mounting space, contact method, routing and tests. Sketches and assembly photos can start the review; structure and specifications remain project-specific.</description></item></channel></rss>